Decontamination Unit | 154
The clean end holds 16 lockers.
The SMH 154 and 154 Roamer, 4 shower units and are built for 16 men. The regulations state 4 men per shower, having 4 showers the 154 can cope with 16 men.
The popular 154 SP or 154 H, are chosen with a pumped filter system to pump the filtered wastewater away and a built in water tank to provide the shower water.
The 154R Roamer, complete with a built in generator in a separate compartment, sited in the dirty end, but accessible only from outside. The Unit is fitted with a water tank to take the filtered shower wastewater. The 154RT with a Tracker covertly built into the unit during construction. More important on larger investments to protect it with a Tracker.
Four Stage Units – The Future of Decontamination Units
When a large number of men are using the Unit it is more important to ensure they decontaminate properly, we suggest a 4-Stage Unit. This elevates the need to turn off the showers while drying – with a queue of men waiting to use the shower unit.
Dirty Area - Remove contaminated clothing and enter shower with mask on.
Removable NPU Decon 400 Air Extractor to assist in DOP tests, Mirror to adjust face mask, Coat Hooks, Bench Seat, Bench Seat Storage, Electric and natural Light, Electric Heating, Warning Signs, Self Closing door at rear of unit to outside.
Shower Area – Shower mask and when clean remove, clean mask and respiratory equipment before showering clean, when finished enter drying room.
4 adjustable showers, Mask Hook, GRP wash hand basins, Electric and natural Light, Self Closing door to dirty area.
Drying Room – Thoroughly clean mask in purpose made washbasin, dry off using a disposable towel while other operative are showering.
Clean End – Thoroughly dry using a cotton towel and dress leaving the unit clean and completely decontaminated.
16 Personal Lockers with electrical sockets for charging respirators, Mirror to adjust face mask, Coat Hooks, Bench Seat or Bench Seat Storage, Electric and natural Light, Electric Oil Filled Radiator, Certificate Holders, Warning Signs, Self Closing door to shower area.
All 154 series units have the following features:
Lightweight pre-formed galvanised chassis, 25mm lightweight insulated panels, solid roof with roof lights containing fluorescent lights, spoiler with gas water heater and gas bottle cupboard, external utility cupboards housing electrics, plumbing and gas, with pumped filter system when fitted, access to wash hand basin plumbing therefore all the services are accessible from the outside assisting on site maintenance.
The doors have keyless push button Digi-locks with the dirty door having an ali-angle surround to enable the tent to be fixed without the need for tape or Spray Tak to be adhered to the unit. One Way Vents and new for 2005 Integrated Pull Out Metal Steps. Fibreglass Floors having rounded corners with Drain Point in each compartment, Self Closing doors.
Optional extras (any options available):
Click here for further product information
To contact SMH Products about Decontamination Unit | 154 use Get a quote.
The clean end holds 16 lockers.
The SMH 154 and 154 Roamer, 4 shower units and are built for 16 men. The regulations state 4 men per shower, having 4 showers the 154 can cope with 16 men.
The popular 154 SP or 154 H, are chosen with a pumped filter system to pump the filtered wastewater away and a built in water tank to provide the shower water.
The 154R Roamer, complete with a built in generator in a separate compartment, sited in the dirty end, but accessible only from outside. The Unit is fitted with a water tank to take the filtered shower wastewater. The 154RT with a Tracker covertly built into the unit during construction. More important on larger investments to protect it with a Tracker.
Four Stage Units – The Future of Decontamination Units
When a large number of men are using the Unit it is more important to ensure they decontaminate properly, we suggest a 4-Stage Unit. This elevates the need to turn off the showers while drying – with a queue of men waiting to use the shower unit.
Dirty Area - Remove contaminated clothing and enter shower with mask on.
Removable NPU Decon 400 Air Extractor to assist in DOP tests, Mirror to adjust face mask, Coat Hooks, Bench Seat, Bench Seat Storage, Electric and natural Light, Electric Heating, Warning Signs, Self Closing door at rear of unit to outside.
Shower Area – Shower mask and when clean remove, clean mask and respiratory equipment before showering clean, when finished enter drying room.
4 adjustable showers, Mask Hook, GRP wash hand basins, Electric and natural Light, Self Closing door to dirty area.
Drying Room – Thoroughly clean mask in purpose made washbasin, dry off using a disposable towel while other operative are showering.
Clean End – Thoroughly dry using a cotton towel and dress leaving the unit clean and completely decontaminated.
16 Personal Lockers with electrical sockets for charging respirators, Mirror to adjust face mask, Coat Hooks, Bench Seat or Bench Seat Storage, Electric and natural Light, Electric Oil Filled Radiator, Certificate Holders, Warning Signs, Self Closing door to shower area.
All 154 series units have the following features:
Lightweight pre-formed galvanised chassis, 25mm lightweight insulated panels, solid roof with roof lights containing fluorescent lights, spoiler with gas water heater and gas bottle cupboard, external utility cupboards housing electrics, plumbing and gas, with pumped filter system when fitted, access to wash hand basin plumbing therefore all the services are accessible from the outside assisting on site maintenance.
The doors have keyless push button Digi-locks with the dirty door having an ali-angle surround to enable the tent to be fixed without the need for tape or Spray Tak to be adhered to the unit. One Way Vents and new for 2005 Integrated Pull Out Metal Steps. Fibreglass Floors having rounded corners with Drain Point in each compartment, Self Closing doors.
Optional extras (any options available):
Click here for further product information
To contact SMH Products about Decontamination Unit | 154 use Get a quote.