Ferrite Meter | MF300Fe+
Industrial processing and chemical plants work at high temperatures and pressures, with often aggressive media and stainless steel is often the material of choice for these applications. If the ferrite content of the steel is too low, then welding of stainless material may crack at elevated temperature or with high stress or vibration. Alternatively, if the ferrite content is too high, the weld may be weaker and corrode.
To address the need to measure the amount of ferrite in a sample the Welding Research Council introduced the Ferrite Number (FN) as standardised value which related to the ferrite content of an equivalently magnetic weld metal.
It has a probe that is sensitive to ferrite content in a 10 mm area to a depth of approximately 1 mm. The instrument is calibrated using the secondary weld standards validated by National Institute of Standards and Technology (NIST) in the USA. All 16 standards are used in the calibration giving an instrument with a measurement range from 0 to 115 FN. Transfer standards are supplied with the instrument allowing performance to be verified at any time.
Features:
To contact Russell Fraser Sales NDT about Ferrite Meter | MF300Fe+ use Get a quote.
Industrial processing and chemical plants work at high temperatures and pressures, with often aggressive media and stainless steel is often the material of choice for these applications. If the ferrite content of the steel is too low, then welding of stainless material may crack at elevated temperature or with high stress or vibration. Alternatively, if the ferrite content is too high, the weld may be weaker and corrode.
To address the need to measure the amount of ferrite in a sample the Welding Research Council introduced the Ferrite Number (FN) as standardised value which related to the ferrite content of an equivalently magnetic weld metal.
It has a probe that is sensitive to ferrite content in a 10 mm area to a depth of approximately 1 mm. The instrument is calibrated using the secondary weld standards validated by National Institute of Standards and Technology (NIST) in the USA. All 16 standards are used in the calibration giving an instrument with a measurement range from 0 to 115 FN. Transfer standards are supplied with the instrument allowing performance to be verified at any time.
Features:
To contact Russell Fraser Sales NDT about Ferrite Meter | MF300Fe+ use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.